The model
Volumetric flow rate is the volume passing a boundary per unit time. At the same flow rate, a smaller cross-section produces a higher average velocity. For steady incompressible flow, continuity is written as Qᵥ = Av.
The power transferred from a pump to a fluid is the pressure difference multiplied by volumetric flow. Shaft power also accounts for pump efficiency. Use Pa and m³/s in this calculation; convert bar and m³/h first.
Worked example
A pressure difference of 2 bar, flow of 10 m³/h and efficiency of 0.70 require approximately 0.794 kW of shaft power.
Scope & assumptions
Pipe friction, valve losses, static elevation and cavitation risk need separate assessment. One power figure is not sufficient to select a pump. Check the manufacturer's curve together with the operating point.
TRY IT YOURSELF
Check your understanding.
What happens to the required power if flow doubles while pressure difference and efficiency remain constant?
Sign-in required. Calculator interface currently in Turkish.